Based on 1.80 m retained width after discounting the largest exit.
Plan the exit.
Know the time.
Inputs
Set the scenario
people
Exit widths
Enter the clear usable width of each exit.
Use the narrowest effective width in the route. The Green Guide notes that route condition, audience profile and event conditions can reduce practical flow.
Results
Evacuation estimate
All exits in use
04:04
4.07 minutes · 246 people / minute
Largest exit discounted
08:08
8.13 minutes · 123 people / minute
Total usable width
3.00 m
Across 2 exits
Calculation breakdown
capacity ÷ throughput
1,000
÷
246
=
4.07 min
peoplepeople / minuteall-exit time
Exit performance
Level surface02
Method
Simple inputs. Visible assumptions.
Flow rate is taken from the SGSA Green Guide egress guidance: 82 persons per metre per minute on a level surface, or 66 on a stepped surface. Evacuation time is calculated as people ÷ (usable exit width × flow rate). Low-risk reference: An open-air route may be treated as lower risk where combustible materials are limited and exits are clear and well managed. Green Guide worked examples use up to 8 minutes.